1.
Rev. bras. ginecol. obstet ; 43(3): 190-199, Mar. 2021. tab, graf
Article in English | LILACS | ID: biblio-1251302

ABSTRACT

Abstract Objective To compare hand-held breast ultrasound (HHBUS) and automated breast ultrasound (ABUS) as screening tool for cancer. Methods A cross-sectional study in patients with mammographically dense breasts was conducted, and both HHBUS and ABUS were performed. Hand-held breast ultrasound was acquired by radiologists and ABUS by mammography technicians and analyzed by breast radiologists. We evaluated the Breast Imaging Reporting and Data System (BI-RADS) classification of the exam and of the lesion, as well as the amount of time required to perform and read each exam. The statistical analysis employed was measures of central tendency and dispersion, frequencies, Student t test, and a univariate logistic regression, through the odds ratio and its respective 95% confidence interval, and with p<0.05 considered of statistical significance. Results Atotal of 440 patientswere evaluated. Regarding lesions,HHBUS detected 15 (7.7%) BI-RADS 2, 175 (89.3%) BI-RADS 3, and 6 (3%) BI-RADS 4, with 3 being confirmed by biopsy as invasive ductal carcinomas (IDCs), and 3 false-positives. Automated breast ultrasound identified 12 (12.9%) BI-RADS 2, 75 (80.7%) BI-RADS 3, and 6 (6.4%) BI-RADS 4, including 3 lesions detected by HHBUS and confirmed as IDCs, in addition to 1 invasive lobular carcinoma and 2 high-risk lesions not detected by HHBUS. The amount of time required for the radiologist to read the ABUS was statistically inferior compared with the time required to read the HHBUS (p<0.001). The overall concordance was 80.9%. A total of 219 lesions were detected, from those 70 lesions by both methods, 126 only by HHBUS (84.9% not suspicious by ABUS) and 23 only by ABUS. Conclusion Compared with HHBUS, ABUS allowed adequate sonographic study in supplemental screening for breast cancer in heterogeneously dense and extremely dense breasts.


Resumo Objetivo Comparar a ultrassonografia convencional das mamas (US) com a ultrassonografia automatizada das mamas (ABUS) no rastreio do câncer. Métodos Realizamos um estudo transversal com pacientes com mamas mamograficamente densas, sendo avaliadas pela US e pela ABUS. A US foi realizada por radiologistas e a ABUS por técnicos de mamografia e analisada por radiologistas especializados em mama. A classificação Breast Imaging Reporting and Data System (BIRADS) do exame e das lesões o tempo de leitura e de aquisição foram avaliados. A análise estatística foi realizada através de medidas de tendência central, dispersão e frequências, teste t de Student e regressão logística univariada, através do odds ratio, com intervalo de confiança de 95%, e com p<0,05 sendo considerado estatisticamente significante. Resultados Foram avaliadas 440 pacientes. Em relação às lesões, a US detectou 15 (7,7%) BI-RADS 2, 175 (89,3%) BI-RADS 3 e 6 (3%) BI-RADS 4, das quais 3 foram confirmadas, por biópsia, como carcinomas ductais invasivos e 3 falso-positivos. A ABUS identificou 12 (12,9%) BI-RADS 2, 75 (80,7%) BI-RADS 3 e 6 (6,4%) BI-RADS 4, incluindo 3 lesões detectadas pela US e confirmadas como carcinomas ductais invasivos, além de 1 carcinoma lobular invasivo e 2 lesões de alto risco não detectadas pela US. O tempo de leitura dos exames da ABUS foi estatisticamente inferior ao tempo do radiologista para realizar a US (p<0,001). A concordância foi de 80,9%. Um total de 219 lesões foram detectadas, das quais 70 por ambos os métodos, 126 observadas apenas pela US (84,9% não eram lesões suspeitas no ABUS) e 23 apenas pela ABUS. Conclusão Comparado à US, a ABUS permitiu adequado estudo complementar no rastreio do câncer de mamas heterogeneamente densas e extremamente densas.


Subject(s)
Humans , Female , Adult , Aged , Young Adult , Breast Neoplasms/diagnostic imaging , Ultrasonography, Mammary/instrumentation , Cross-Sectional Studies , Sensitivity and Specificity , Equipment Design , Middle Aged
2.
Radiol. bras ; 51(6): 351-357, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-976750

ABSTRACT

Abstract Objective: To demonstrate the frequency of malignancy and histological characteristics of lesions in patients submitted to vacuum-assisted breast biopsy guided by magnetic resonance imaging (MRI). Materials and Methods: This was a retrospective study of MRI-guided vacuum-assisted breast biopsies performed between April 2008 and December 2016, in which we analyzed clinical and epidemiological data, as well as the BI-RADS classification and histopathological results. We compared nodules and non-nodular enhancements, in terms of their correlation with malignancy, using chi-square test. Results: Among 215 cases referred for MRI-guided vacuum-assisted breast biopsy, the procedure was contraindicated in 10 cases (5%) and was technically feasible in the remaining 205 (95%). Non-nodular enhancements were observed in 135 cases (66%), and nodules were observed in 70 (34%), with a mean diameter of 2.2 cm (range, 0.5-9.6 cm) and 0.97 cm (range, 0.5-2.2 cm), respectively. Of the 205 lesions analyzed, 43 (21%) were malignant, 129 (63%) were benign, and 33 (16%) were classified as high-risk lesions. The most common histological findings were invasive ductal carcinoma and, in high-risk cases, lobular neoplasia. There was no significant difference between nodules and non-nodular enhancements in terms of the rate of malignancy (p = 0.725). Conclusion: In our sample, the overall malignancy rate was 21%. However, to improve the assessment of these results, it is necessary to correlate them with the surgical data and with data from the follow-up of benign cases.


Resumo Objetivo: Demonstrar a frequência de malignidade e as características histológicas das lesões encontradas em pacientes submetidas a biópsia a vácuo guiada por ressonância magnética (RM). Materiais e Métodos: Estudo retrospectivo, realizado no período de abril de 2008 a dezembro de 2016, de biópsia a vácuo guiada por RM, em que se analisaram dados clinicoepidemiológicos, classificação BI-RADS e resultados histopatológicos. A comparação entre os nódulos e os realces não nodulares e a presença de malignidade foi realizada utilizando-se o teste de qui-quadrado. Resultados: Dos 215 casos com indicação de biópsia a vácuo guiada por RM, 10 (5%) foram contraindicados e os restantes 205 (95%) foram tecnicamente viáveis. Foi observado que 66% eram realces não nodulares (135 lesões) e 34% eram nódulos (70 lesões), medindo, em média, 2,2 cm (0,5-9,6 cm) e 0,97 cm (0,5-2,2 cm), respectivamente. Das 205 lesões analisadas, 43 (21%) eram malignas, 129 (63%) eram benignas e 33 (16%) eram de alto risco. O achado histológico mais frequente nos casos de malignidade foi o carcinoma ductal infiltrante, e nos casos de alto risco, as neoplasias lobulares. Não houve diferenças estatisticamente significantes entre os nódulos e realces não nodulares em relação a malignidade (p = 0,725). Conclusão: Na nossa amostra, a taxa global de malignidade foi de 21%. No entanto, é necessário correlação com dados cirúrgicos e seguimento nos casos benignos, para melhor avaliação dos resultados.